INTRODUCE
SR81 Controller Is The Updated Version Of The SR868C8 Controller .
SR81 - 1.5KW version
SR81 - 3KW version
SR81 - 4KW version
For below solar hot water system :
Split type high pressure system
Split type Low / Non pressure system + Assistant tank with float ball
APPLICATIONS CAPACITY
Max.number of collectors:1
Max.number of storage tanks:1
Max.number of relays:4
Max.number of sensors:5
Max.number of visualization application system: 1
FRT:1* Rotary vane type electron flow meter
TECHNICAL DATA
Size of Display panel (1.5/3/4KW version):120mm x 120mm x 18mm
Size of Controller board (1.5KW version): 187mm x128mm x46mm
Size of Controller board (3KW/4KWversion): 218mm x165mm x55mm
Power supply: AC100-240V,50-60Hz. .
Power consumption: < 2.5W
Rated impulse voltage: 2.5KV
Housing: Plastic ABS
Protection type: IP40
Mounting: Wall mounting
Operation: 10 push buttons at the front cover.
Accuracy of temperature measuring: ± 0.1oC
Range of collector temperature measuring: -10oC ~220oC
Range of tank temperature measuring: 0oC ~110oC
Suitable power of pump: 3 pump possible to be connected
Suitable power of HK (backup heating):
1pc(1.5KW version) ˂1.5KW
1pc(3KW version) ˂3KW
1pc(4KW version) ˂4KW
Inputs: 5 sensors,
1pcs*Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC),
2pcs*NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC cable ≤105oC),
1pcs*NTC10K, B3950 sensor (≤ 135oC) for DHW pipeline , (PVC cable ≤105oC),- Optional
1pcs*NTC10K, B3950 sensor (≤ 135oC) for thermostat function , (PVC cable ≤105oC), - Optional
#1*FRT Rotary vane type electron flow meter
Outputs: 4 relays,
R1,R2,R3 relay, for control pump or valve , Max.current 2A
HR relay(1.5KW version)for on/off control of back-up heating , Max. Current 10A ( @AC230V, for 1500W electrical heater,@110VAC, for 750W electrical heater)
HR relay(/3KW version)for on/off control of back-uheating , Max. Current 15A ( @AC230V, for 3000W electrical heater,@110VAC, for 1500W electrical heater)
HR relay(4KW version)for on/off control of back-up heating , Max. Current 20A ( @AC230V, for 4000W electrical heater,@110VAC, for 2000W electrical heater)
Ambient temperature: -10oC ~ 50oC.
Water proof grade: IP41
Display Panel
Terminal allocation of controller for electrical heater of 1500W
Terminal allocation of controller for electrical heater of 3000W/4000W
Delivery list
1 * SR81 controller
1 * accessory bag
1 * user manual
1 * PT1000 temperature sensor (φ6*50mm,cable length 1.5meter)
2 * NTC10K temperature sensor (φ6*50mm,cable length 3meter)
1 *10A power cable ( Note: controller for 3000W/4000W electrical heater has no power cable delivered, user should prepare a cable of 2.5mm2)
Main functions:
DATE---Date setting
Timed heat---backup heating
Circle---Hot water circulation
LOAD---Setup Loading tank1
COL---Collector1
PUMP---Pump control mode
COOL---Cooling function
AUX---Auxiliary function
MAN---Manual mode
BLPR---Blocking protection function
OTDI---Thermal disinfection function
FS---Flow meter type selection.
UNIT---C-F unit switch
RST---factory setting
PASS--- password set
Holiday function
Screen Protection
Trouble Protection
Trouble Checking